Skip to content
Discuss Your Project
  1. Home
  2. Blog
  3. What are the key considerations in clinic interior design?

What are the key considerations in clinic interior design?

14 min read

The key clinic interior design considerations are seven: specialty fit, flow, hygienic surfaces, privacy, patient trust, accessibility and fire safety, and sustainability. Clinic interior design considerations begin with the rules of the specialty. In Turkey, a dental treatment room must be at least 12 m² and hold one dental unit. Antimicrobial coatings do not replace cleaning.

ElementWhat to checkExample criterionBasis
Fit to the specialtyTreatment list, equipment, number of rooms, licence typeDental treatment room at least 12 m², no more than 1 unit per roomTurkish oral and dental health regulation, arts. 8 and 9
Patient and staff flowPatient route, staff route, dirty and clean material routesClean and dirty activities separated; separate stores for cleaning equipment, linen and clinical wasteDepartment of Health (England), HBN 00-09
Hygienic surfacesFloors, walls, worktops, furniture, light fittingsNo carpet in clinical areas; floor coved up the wall, joints welded or sealedHBN 00-09, 3.110–3.115
Privacy and acousticsSound, sight and noise47 dB DnT,w on site between two adjacent consulting roomsDepartment of Health (England), HTM 08-01
Patient experience and trustWaiting area, order, light, viewsHigher perceived quality of care in clinics rated more attractive (r = 0.335)Becker and Douglass, 2008
Accessibility and fireEntrance, doors, lift, toilet, escape, lining classInternal door clear width 90 cm in buildings approved after 1 October 2017; 150 × 150 cm manoeuvring space in accessible toiletsTurkish accessibility monitoring and inspection form
SustainabilityEnergy, product life, layout flexibilityHealth care's climate footprint about 4.4% of global net emissionsHealth Care Without Harm, 2019
Checklist for the seven elements of clinic interior design; criteria are examples and vary by facility type. Source: Turkish Ministry of Health regulations (as of November 2026); Department of Health (England), HBN 00-09 and HTM 08-01, 2013; Becker and Douglass, 2008; Turkish Ministry of Family and Social Services accessibility form; Health Care Without Harm, 2019

How do clinic interior design considerations change by specialty?

The first decision in clinic interior design is the specialty: its treatments set the rooms, their size, the equipment and the licence type. A specialty fit analysis checks treatments, equipment and patient numbers against those rules before design begins. In Turkey, the regulation for physicians' practices requires a separate examination room for each physician and "the conditions required by the specialty".

This rule is in Article 13 of Turkey's Regulation on Private Health Facilities Providing Outpatient Diagnosis and Treatment. As a rule, up to three physicians may practise in one flat; the limit applies to new practices and those moving address. Dentistry has its own Regulation on Private Health Facilities Providing Oral and Dental Health Services. Each unit sits in its own room, and a dental practice may have no more than two units per dentist.

SpecialtyCriterion that shapes the spaceBasis
DentistryTreatment room at least 12 m², no more than 1 unit per room; in a dental practice, no more than 2 units per dentistTurkish oral and dental health regulation, arts. 8/1-a, 8/1-c and 9/1
Physician's practice (any specialty)Separate examination room for each physician plus the conditions required by the specialty; no more than 3 physicians per flat for new or relocating practicesTurkish outpatient regulation, art. 13/2 and provisional art. 6
OphthalmologyViewing distance for distance acuity testing; at least 4 m for expert assessments in GermanyWesemann et al., 2020 (DIN 58220-3)
Hair transplantationProcedure room at least 16 m²; photography area outside the roomTurkish Regulation on Hair Transplant Units, art. 6/5-c and 6/5-d
Aesthetic laser treatmentsLaser controlled area enclosed by room walls or ceiling-hung curtains; reflective surfaces such as windows and mirrors are risk assessedMHRA (UK), laser safety guidance, 2015, 5.2 and 5.8
Psychiatry and therapySpeech privacy: counselling rooms are classed "confidential" with high noise generation; raised speech is not intelligible next doorDepartment of Health (England), HTM 08-01, 2013, Table 3
Main criteria that shape the interior by specialty; Turkish provisions as of November 2026, others from the guidance of the source country. Source: Turkish Ministry of Health regulations; Wesemann et al., Der Ophthalmologe 117, 2020; MHRA, 2015; Department of Health (England), HTM 08-01, 2013

The output is a room and equipment list: each room's area and each device's water, power or air connections. Our article on requirements for opening a dental clinic covers Turkey's dental facility types; confirm current provisions with the provincial health directorate.

How are patient, staff and material flows separated in a clinic?

A clinic has three flows to plan separately: patients, staff, and dirty items going to cleaning and back. England's health building guidance HBN 00-09 treats a clear split between clean and dirty work as a design principle.

The guidance wants cleaning equipment, linen and clinical waste kept in their own dedicated stores, so they cannot contaminate one another. In outpatient rooms used for examinations or procedures, the clinical hand-wash basin sits near the point of care. HBN 00-09 also asks for enough storage to prevent clutter and for needless ledges, such as window sills, to be left out.

In a dental clinic, the most sensitive flow is instruments going to sterilisation and back; see our article on the sterilisation room. Building services follow the flow: Turkey's dental regulation requires adequate ventilation, heating and cooling in all areas (art. 7/1, 7/3). We advise against fixing service outlets until the room and equipment list is final.

Which surfaces are hygienic in a clinic, and are antimicrobial materials needed?

A hygienic clinic surface is impervious, smooth, as jointless as practicable and unaffected by cleaning agents. An antimicrobial label does not replace these basics. HBN 00-09 noted that, as of its 2013 publication, there was no conclusive evidence that antimicrobial coatings, paints or curtains cut healthcare-associated infections. Turkey's dental regulation likewise requires floors that are easy to clean and disinfect (art. 7/2).

HBN 00-09 gives measurable detail. Hard flooring is coved a short way up the wall, with welded or sealed joints. Timber floors and floors with unsealed joints are avoided, and carpet is ruled out in clinical areas. Light fittings should be easy to clean and not gather dust: flush ceiling fittings are acceptable, open up-lights are not.

The trial data we found concern copper alloys. A copper alloy label registered by the US Environmental Protection Agency (EPA) reports laboratory results for regularly cleaned surfaces. Within two hours, the surface killed more than 99.9% of the five bacterial species tested. The label adds that copper complements routine infection control and does not replace it.

Clinical evidence is limited. In a 2013 randomised trial by Salgado and colleagues in the intensive care units of three hospitals, the infection rate was 0.081 in standard rooms. In rooms with copper alloy surfaces it was 0.034. The authors say the effect needs confirming in other patients and settings; we found no comparable outpatient study.

Surface typeWhat the source saysWhat it means for clinic design
Copper alloy (high-touch surfaces)EPA-registered label: on regularly cleaned surfaces in laboratory tests, more than 99.9% of the five bacterial species tested killed within two hours; infection rate in intensive care 0.034 versus 0.081A supporting measure; cleaning and disinfection continue unchanged
Antimicrobial-impregnated coatings, paints and curtainsHBN 00-09: no conclusive evidence, as of 2013, that they reduce healthcare-associated infectionsNot a selection criterion; durability and cleanability decide
Antimicrobial textiles and mattressesCDC (2003): caution about using them in place of standard items; EPA had not then approved claims of protection against human pathogens for treated articlesKeep upholstery in good repair and mend tears and holes
Bactericidal or fungicidal treatment of carpetCDC: no recommendation for routine use (unresolved issue)Jointless hard flooring instead of carpet in clinical areas
Types of antimicrobial surface and what the sources say. Source: EPA, Antimicrobial Copper Alloys Group I label (registration no. 82012-1, 2009); Salgado et al., Infection Control & Hospital Epidemiology 34(5), 2013; Department of Health (England), HBN 00-09, 2013; CDC, Guidelines for Environmental Infection Control in Health-Care Facilities, 2003

How are privacy, sound and light achieved in a treatment room?

Privacy in a treatment room has three layers: speech unintelligible next door, the patient unseen when the door opens, and no intrusive outside noise. Turkey's dental regulation requires arrangements for patient privacy in terms of sound, sight and noise (art. 8/1-a).

Turkey's Regulation on the Protection of Buildings against Noise covers all public and private buildings, changes of use and major alterations (art. 2). Non-compliant projects get no building permit (art. 5/2). England's acoustic guidance gives detailed targets.

The Department of Health's HTM 08-01 places consulting, examination and treatment rooms in its "confidential" class. In that class, a raised voice can be heard next door, but the words cannot be made out. Its worked example needs 47 dB DnT,w on site between adjacent consulting rooms, meaning a lightweight partition of Rw 56 dB. External noise limits are 40 dB in these rooms and 50 dB in waiting areas (LAeq, 1 hour).

A door significantly downgrades a partition. HTM 08-01 puts a typical doorset at Rw 30–35 dB. So for a partition containing a door, going above Rw 40–45 dB brings no acoustic benefit unless high-performance doorsets or lobbies are used. We recommend placing the examination couch out of view of the corridor.

Lighting has two needs: strong, shadow-free task light for examination and softer general light for waiting. Turkey's dental regulation requires "adequate" lighting but sets no values (art. 7/1).

How do you create a clinic interior that builds trust?

In our view, trust grows when hygiene and function are visible to the patient, so hygiene, function and trust are designed together. Becker and Douglass's study, published in 2008, observed 787 patients and collected 205 surveys at Weill Cornell Medical Center's outpatient units in New York. Where settings were rated more attractive, perceived quality of care, staff interaction and anxiety relief were higher.

The correlations are moderate (r = 0.335 for quality of care) and do not prove cause and effect. In Becker and Douglass's paper, measured waiting time was not linked to perceived quality, while perceived waiting time was. Our guide to clinic waiting room design covers room size and seat numbers.

Daylight and views matter too. In Ulrich's 1984 study in Science, 23 patients with a view of trees stayed 7.96 days on average. Matched patients facing a brick wall stayed 8.70 days. The study involved inpatients after gall bladder surgery and does not transfer directly to outpatient clinics.

Trust also needs legibility. We think patients should see reception, the waiting area and the toilet on entering, with sterilisation and dirty areas out of sight. Turkey's dental regulation also requires a sign on every room and unit door stating its purpose (art. 7/5).

How do accessibility, fire safety and licensing affect clinic interiors?

Accessibility, fire and licensing rules set the limits: door widths, toilets, lifts, escape routes and lining fire classes. Under Turkey's dental regulation, a polyclinic not on the entrance floor needs a lift that can carry a wheelchair user. Without a lift, a stair lift or lifting platform may be used (art. 9/2).

Dimensions come from the Ministry of Family and Social Services' accessibility monitoring and inspection form for buildings. In buildings approved after 1 October 2017, internal doors need a clear width of at least 90 cm. Accessible toilets in inspected buildings approved after 30 May 2019 need 150 × 150 cm of manoeuvring space, excluding fixtures.

Fire rules depend on the building's use class. Turkey's Regulation on the Fire Protection of Buildings treats doctors' and dentists' practices as offices (art. 12/1). Buildings where four or more people can be admitted as patients, including private clinics, fall in the healthcare class (art. 11/1-b). Offices, practices included, and outpatient centres generally need at least two independent escape stairs or exits.

One stair suffices only if all conditions are met, such as height below 21.50 m and under 50 occupants per floor (art. 52). Wall linings and floor coverings must be at least normally flammable, and at least flame-retardant in high-rise buildings (art. 26/2, 29/3). Check current fire rules with the municipality and fire service.

After licensing, the dental regulation bars changes to licensed physical areas without the provincial health directorate's permission (art. 27/2-ç). The outpatient regulation allows deviations of up to 2% from minimum dimensions (art. 6/2); the dental regulation has no such tolerance. Confirm health provisions with the provincial health directorate.

What makes clinic architecture sustainable?

Sustainable clinic architecture means low-energy systems, durable and repairable materials, and a layout that allows future change. A 2019 report by Health Care Without Harm estimates the health sector's emissions at roughly 4.4% of the world's net total. The estimate uses 2014 data.

Facilities and their vehicles produce 17% directly; bought-in electricity, heating and cooling add 12%. The other 71% is supply chain: making, moving and disposing of medicines, devices and hospital equipment. In our view, interior design affects two of these: lighting and air-conditioning energy, and product life.

HBN 00-09 asks designers to weigh whole-life costs, including cleaning and maintenance, rather than the cheapest product. The most tangible step is durable surfaces that withstand disinfectants. The second is flexibility: licensed areas cannot be altered without permission, so service capacity for future rooms or units is planned from the start.

Which specialties has Picco Architecture designed clinics for?

Picco Architecture's archive lists 131 healthcare-category projects from 2015 to 2026, including a dental laboratory and a dental supply store. Of these, 126 are dental clinics: 122 in Turkey, 4 abroad. Outside dentistry are a hair transplant centre, a medical aesthetics clinic and a beauty centre. Projects span 21 Turkish provinces plus Kyrgyzstan, Iraq, Iran, the United Kingdom and Azerbaijan.

  • 131project records in the healthcare category, 2015–2026
  • 126dental clinics: 122 in Turkey, 4 abroad
  • 21provinces in Turkey
  • 5countries abroad
  • 15procedure rooms: AHD Hair Transplant Centre, Antalya
Number, spread and specialties of Picco Architecture's healthcare project records. Source: Picco Architecture project archive, November 2026

The dental clinics are 98 polyclinics (2 in Bishkek and Najaf), 19 practices, 6 oral and dental health centres and 1 hospital. Two more are in London and Iran. The AHD Hair Transplant Centre in Antalya covers 900 m². Dünya Estetik Clinic (Elixir Aesthetic Center) in Baku covers 1,400 m², and Plumeart Beauty Center in Antalya 350 m².

Abroad, host-country rules apply instead of Turkish ones. Picco Architecture's general approach is to fix the specialty's room and equipment list, then the flows, before colours and materials. See all our healthcare projects, or our clinic design FAQ for further questions.

Let’s discuss your clinic project.

Leave a few details and our team will get in touch to discuss the scope, the budget and the next steps.

On-site surveys of existing premises are free of charge.

Prefer to talk now? WhatsApp Call Picco Architecture: +90 850 532 10 50

Type of facility
Do you have premises?
Contact Details
How did you hear about us? (Optional)

Please confirm that you have read the privacy notice to continue.

Frequently asked questions

What is the difference between clinic architecture and clinic interior design?

Clinic architecture covers the building's siting, structure, facade, floors, stairs and lifts. Clinic interior design sets partitions, room layout, surfaces, furniture, lighting and service outlets inside that shell. In an existing building, most of the work is interior design. Yet the lift, escape stair and entrance level are architectural decisions that affect the licence directly.

Which standards apply to clinic design?

In Turkey, the binding rules are the health regulation for the facility type, the fire and noise protection regulations, and accessibility law. Where they give no figures, designers use guidance such as England's HBN and HTM documents and CDC guidelines. These are not binding in Turkey but help justify design decisions.

Can a clinic have plants and flowers?

The US Centers for Disease Control and Prevention (CDC) see no need to keep flowers and potted plants away from patients with normal immunity. Where patients are immunosuppressed, fresh or dried flowers and potted plants are not allowed. In our view, plants belong in the waiting area, away from treatment and sterilisation rooms.

Can carpet be used in a clinic?

HBN 00-09 rules out carpet in clinical areas, including corridors and entrances where spills are likely. Carpet in non-clinical spaces such as interview or counselling rooms needs a local risk assessment with the infection control team and a planned cleaning programme. The CDC likewise advises against carpet in busy patient-care areas and where spills can be expected.

Starting from the specialty's room and equipment list gives decisions on flow, hygiene and privacy a base that will not shift later. To discuss your project with your specialty and premises in mind, please contact us.