Hotel room size in Türkiye depends on the star rating. As of November 2026, the rule sits in the Regulation on the Qualifications of Tourism Facilities. It requires at least 25 m² including the bathroom in 5-star hotels and holiday villages, and at least 20 m² in 4-star ones. Hotels with 1 to 3 stars have no minimum; a room of up to 10 m², excluding the bathroom, may be arranged as a single.

ItemMeasureScope and note
5-star hotel and holiday villageAt least 25 m² including bathroomExcludes facilities in protected immovable cultural property
4-star hotel and holiday villageAt least 20 m² including bathroomSame exemption applies
Single and double roomsUp to 10 m² excluding bathroom: singleLarger rooms may be doubles; applies to all accommodation facilities
SuiteAt least two sectionsOne section is a sitting area; no separate minimum, the general 20/25 m² applies at 4 and 5 stars
Beds counted in a suiteUp to 60 m² including bathroom: 2 bedsAbove 60 m² with more than one bedroom: 4 beds
Accessible rooms1% of rooms, at least 1Facilities with 80 or more rooms, and 4- and 5-star hotels and holiday villages
ToleranceUp to 10%At the Ministry's discretion
Provisions of the Turkish regulation that directly set room size, as of November 2026. Source: Ministry of Culture and Tourism, Regulation on the Qualifications of Tourism Facilities, 2019 (room size amendment: 22 December 2024)

What hotel room size does Turkish regulation require?

In Türkiye, Article 18 of the Regulation on the Qualifications of Tourism Facilities sets hotel room size. Since 22 December 2024, 5-star hotels and holiday villages need at least 25 m² (about 269 sq ft). In 4-star hotels and holiday villages the minimum is 20 m² (about 215 sq ft); both figures include the bathroom. Facilities in protected immovable cultural property are exempt.

The regulation was first published in the Official Gazette of 1 June 2019, issue 30791. The room size amendment appeared in issue 32760 of 22 December 2024 and took effect the same day. The latest amendment, in August 2026, did not change room sizes. Check the current text in the regulation on mevzuat.gov.tr and with the Ministry of Culture and Tourism.

Hotels with 1, 2 or 3 stars have no minimum room area. The general measure for all accommodation facilities is the split between single and double rooms. A room of up to 10 m², excluding the bathroom, may be a single; a larger room may be a double. The articles on boutique hotels and apart-hotels set no separate room area either.

A suite has at least two sections, one of them a sitting area, divided by fixed construction. There is no separate minimum for suites; in 4- and 5-star hotels and holiday villages, the general 20/25 m² minimum applies to suites too. In all facilities, the bed count of a suite depends on its area. A suite of up to 60 m², bathroom included, counts as two beds; above 60 m² with more than one bedroom, it counts as four.

Since December 2024, every room in a suite arranged with a bathroom, including the sitting area, counts as a bedroom for the bed count. For facilities certified before the amendment, the new suite rules apply from 1 January 2028. If the facility adds bedrooms, this deferral no longer applies to the whole property.

Under a transitional clause, the new room sizes are not required when a facility certified before 22 December 2024 applies for a higher rating. Facilities that held a tourism investment certificate on that date are outside this exemption. Article 9 also allows the Ministry to accept deviations of up to 10% from the regulation's metric limits, considering location, building and function.

Accessible rooms also shape the room mix. Facilities with 80 or more rooms, and 4- and 5-star hotels and holiday villages, must make 1% of their rooms accessible, with at least one. The regulation also prohibits guest bedrooms on floors that lie below ground level and receive no daylight.

How is hotel room size scored in Hotelstars Union countries?

Hotelstars Union, with 22 member countries in Europe and the Caucasus, sets no mandatory minimum room size; it scores area instead. Under its 2025–2030 criteria, a room of at least 14 m², bathroom included, earns 10 points. Rooms of 18, 22 and 30 m² earn 15, 25 and 30. Bathrooms of at least 5 m² and 7.5 m² earn 10 and 15 points.

In Hotelstars Union countries, then, room size earns a score rather than serving as a pass mark. The points are optional; a hotel can reach the total required for its category through other facilities and services. Up to 15% of rooms may fall below the threshold claimed. Guests must be informed of this before they book.

The full list is in the Hotelstars Union classification criteria 2025–2030. The union was founded in 2009. Its member list includes Georgia (HORECA – Hotel Star Georgia), Azerbaijan and Armenia. For an investor planning a hotel in Batumi or Tbilisi, these thresholds are a natural benchmark alongside the Turkish regulation.

Türkiye's mandatory minimums and the voluntary Hotelstars Union point thresholds, room area including bathroom (m²). Source: Regulation on the Qualifications of Tourism Facilities, 2019 (amended 2024); Hotelstars Union, Classification criteria 2025–2030
Show the data as a table
BenchmarkRoom area including bathroom (m²)
Hotelstars Union, 10-point threshold14
Hotelstars Union, 15-point threshold18
Türkiye, 4-star hotel minimum20
Hotelstars Union, 25-point threshold22
Türkiye, 5-star hotel minimum25
Hotelstars Union, 30-point threshold30

The comparison shows two different logics. In Türkiye, area is an entry condition for 4 and 5 stars; under Hotelstars Union it is one scoring item among many. Türkiye's 4-star minimum of 20 m² exceeds the 18 m² threshold worth 15 points. The 5-star minimum of 25 m² clears the 22 m² threshold but stays below 30 m².

How big should a standard room, suite and bathroom be?

No single size is correct for a standard hotel room: regulation sets the floor; budget and site set the ceiling. In Türkiye, the starting point is 20 m² for 4 stars and 25 m² for 5 stars. A planning article in the Cornell Hotel and Restaurant Administration Quarterly uses 32.5 m² (350 sq ft) in an example 300-room programme.

The article, by Walter A. Rutes, Richard H. Penner and Lawrence Adams, was published in 2001. It defines suites as multiples of the standard room module, or bay. With a 32.5 m² bay, a two-bay suite is 65 m², a three-bay suite 97.5 m² and a four-bay presidential suite 130 m². In our view, planning a suite as a multiple of the room module makes it easier to keep the structural grid and service shafts intact.

The Turkish regulation sets no bathroom size; as a rule, it requires bedrooms to have daylight and a bathroom. The sitting area of suites and apart rooms may have no daylight. Since December 2024, the same applies to at most one bedroom in suites, apart rooms and family rooms.

Under Hotelstars Union criteria, a bathroom of at least 5 m² earns 10 points and one of at least 7.5 m² earns 15. Because the Turkish 25 m² includes the bathroom, a 5 m² bathroom leaves 20 m² for sleeping and seating.

A larger bathroom makes the room deeper or the sleeping area narrower, so bathroom size is chosen together with the room module. Wardrobe, desk and luggage space are resolved within the same module. For in-room equipment, see our article on technology products in hotel rooms.

How does room size determine a hotel's total floor area?

Room size drives a hotel's built area through floor efficiency. Floor efficiency is the share of a guestroom floor's gross area taken by saleable rooms. The vertical core, corridors and floor service areas take the rest. Rutes, Penner and Adams report values under 60% for poorly planned atriums and above 75% for the most compact double-loaded slabs.

Guestroom area as a share of gross floor area by guestroom floor configuration (typical values). Source: Rutes, Penner and Adams, Challenges in hotel design: Planning the guest-room floor, Cornell Hotel and Restaurant Administration Quarterly 42(4), 2001
Show the data as a table
Guestroom floor configurationGuestroom share of floor area (%)
Offset slab72
Double-loaded slab70
Circular tower67
Single-loaded slab65
Rectangular tower65
Triangular tower64
Atrium62

The article's target is for guestrooms to occupy at least 70% of the guestroom floor. At that ratio, about 1.43 m² of floor must be built for every 1 m² of room. With rooms on only one side of the corridor, the same room count needs 5–8% more floor area. Picking one plan type over another can shift the guestroom block's gross area by up to 20% and the total building by close to 15%.

Gross guestroom floor area = Number of rooms × Average room area ÷ Floor efficiency

VariableMeaningExample
Number of roomsSaleable rooms (keys)120
Average room areaNet room area including bathroom25 m²
Floor efficiencyRoom area as a share of gross guestroom floor area0.70 or 0.62

Double-loaded slab: 120 × 25 ÷ 0.70 = 4,286 m²; 35.7 m² per room.

Atrium plan: 120 × 25 ÷ 0.62 = 4,839 m²; 40.3 m² per room. The difference of 553 m² is roughly the net area of 22 rooms of 25 m².

Worked example for the guestroom floors of a 120-room hotel at the 5-star minimum. Source for floor efficiencies: Rutes, Penner and Adams, Cornell Hotel and Restaurant Administration Quarterly 42(4), 2001

This calculation covers guestroom floors only; the result grows in step with room area. Lobby, restaurants, kitchen, plant rooms and staff areas are added according to the hotel's concept. In the article's own example, 32.5 m² rooms result in roughly 44–54 m² of gross guestroom floor area per room, depending on the plan type.

What should you weigh when deciding room size?

In hotel room design, room size is not one decision but the result of several linked ones. We recommend fixing the target rating and regulations first, then the structural grid and floor type. Within that frame, room size is fine-tuned to the market and the operating model. The list below sets out these decisions in order.

  1. Target rating. The minimum is 20 m² including the bathroom for 4 stars and 25 m² for 5 stars; facilities in protected immovable cultural property are exempt.
  2. Transitional status. New room sizes are not required when a facility certified before 22 December 2024 upgrades its rating. Facilities that held a tourism investment certificate at that date are outside this exemption.
  3. Structural grid. The Cornell article describes a structural bay as usually one or two rooms wide. Choose the room module together with the grid.
  4. Floor plan type. Floor efficiency is about 70% in a double-loaded slab and 62% in an atrium. The built area needed for the same rooms changes accordingly.
  5. Bathroom layout. Turkish minimums include the bathroom; every square metre given to the bathroom comes out of the sleeping and seating area.
  6. Level and daylight. Guest bedrooms are not allowed on floors below ground level that receive no daylight.
  7. Accessible rooms. Facilities with 80 or more rooms, and 4- and 5-star hotels and holiday villages, must make 1% of rooms accessible, at least one.

Where are Picco Architecture's hotel projects?

Picco Architecture's project archive lists 14 records in the hotel category. Ten are in Georgia, in Batumi and Tbilisi; three are in Antalya and one is in Benghazi, Libya. The Georgian records date from 2023 to 2026 and include two sales offices in Tbilisi alongside hotel projects. The Libyan record is a resort villa project.

  • 14project records in the hotel category
  • 10in Georgia: 5 in Batumi, 5 in Tbilisi
  • 3in Antalya: Kundu, Manavgat and Hotel Design Show 2016
  • 3countries: Georgia, Türkiye and Libya
Distribution of Picco Architecture's project records in the hotel category. Source: Picco Architecture project archive, November 2026

The Batumi records include Orbi City, Orbi Sea Tower, Orbi Beach Tower, Avenue by Orbi and Continental. In Tbilisi, the archive lists Central Park Towers, Radisson Blu and Radisson Collection. In Antalya, it includes Baia Hotel in Kundu and Concept Boutique Hotel in Manavgat. The project list is on our hotel projects page.

The archive also includes Hotel Design Show 2016 in Antalya, the subject of our Hotel Design Show 2016 article. For design criteria at boutique scale, see our article on boutique hotel design.

Let’s discuss your hotel project.

Leave a few details and our team will get in touch to discuss the scope, the budget and the next steps.

Prefer to talk now? WhatsApp Call Picco Architecture: +90 850 532 10 50

Contact Details
How did you hear about us? (Optional)

Please confirm that you have read the privacy notice to continue.

Frequently asked questions

How big should a boutique hotel room be?

The regulation's article on boutique hotels sets no separate room area. The general rule applies instead: a room of up to 10 m², excluding the bathroom, may be a single, and a larger room a double. In a boutique hotel set in an existing building, room size depends largely on the building's structural grid and window pattern.

How big should an accessible hotel room be?

Neither the Turkish regulation nor its implementing communiqué sets an area for accessible rooms. Facilities with 80 or more rooms, and 4- and 5-star hotels and holiday villages, must make 1% of rooms accessible, with at least one. The communiqué requires a room door at least 90 cm wide, and a shower arrangement, seat and grab bars in the bathroom. Area follows from easy wheelchair movement between these elements.

Must an existing hotel meet the 20 m² minimum when upgrading to 4 stars?

Under the transitional clause, the room size rules do not apply to upgrade applications from facilities certified by the Ministry before 22 December 2024. Facilities that held a tourism investment certificate on that date are outside this exemption. Before applying, confirm the facility's certificate type and current practice with the Ministry of Culture and Tourism; this article is not legal advice.

Can a hotel room in a historic building be smaller than 25 m²?

It can if the building is immovable cultural property requiring protection under Turkish law. The regulation exempts facilities in such buildings from the 20 and 25 m² minimums for 4- and 5-star hotels. Check the building's status with the relevant regional conservation council. The 10 m² rule for single and double rooms still applies.

Is there a 10% tolerance on hotel room sizes in Türkiye?

Article 9 of the regulation gives the Ministry this power. Considering location, building and function, the Ministry may accept deviations of up to 10% from the regulation's metric limits. This is a discretion, not a right. In a new project it is safer to plan room sizes above the minimum than to rely on the tolerance.

Fixing room size early, together with the target rating and floor plan, makes every later decision easier. To review your project's room programme and gross area calculation together, get in touch with us.